Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. odonto ciênc ; 23(1): 72-76, jan.-mar. 2008. graf, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-487788

RESUMO

Objetivo: Avaliar a temperatura da câmara pulpar (CP) e do gel clareador bloqueador de infravermelho na superfície dental (SUP), durante a ativação com fotopolimerizadores com lâmpadas halógenas que emitem radiação na faixa do infravermelho (IV). Metodologia: Os géis clareadores Whiteness HP Maxx (com bloqueador de IV - MX) e Whiteness HP (controle - CON) foram aplicados em 10 incisivos centrais superiores. A ativação com luz foi realizada com os fotopolimerizadores (FP) Optilight (600mW/cm2, OP) e Jet Lite (1200mW/cm2, JL), sendo quatro ativações de 40s, sem intervalo (total de 3min e 20s). As temperaturas foram aferidas a cada 40s com um termômetro digital com dois termopares tipo K, um no interior da CP e outro na superfície dental (SUP). Os dados foram analisados com ANOVA a 3 fatores (tipo de gel - TG, FP e tempo de ativação) e teste de Tukey. Resultados: Houve efeito significativo de TG e FP e para a interação FP/TG. As médias (DP) (em graus Celsius) foram: PC:[GT={MX-6,38(3,25)a, CON-7,70(2,91)b}, FC={OP-5,51(2,54)a, JL-8,56(2,93)b}]; SUR: [GT={CON-9,85(3,89)a, MX-14,21(7,76)b}, FC={OP-7,32(2,50)a, JL-16,74(5,82)b}]. Conclusões: O gel bloqueador de IV resultou em menor aquecimento da CP e maior aquecimento do gel que o controle. O FP Jet Lite promoveu maior aquecimento que o Optilight.


Purpose: To evaluate temperature changes of pulpal chamber (PC) and infrared blocking bleaching gel on dental surface (SUR) during the activation with photocuring units with halogen lights that emit radiation in the infrared (IR) range. Methods: The bleaching gels Whiteness HP Maxx (IR-blocker - MX) and Whiteness HP (control - CON) were used in ten maxillary central incisors. Light-activation was performed by using the photocuring units (FC) Optilight (600mW/cm2, OP) or Jet Lite (1200mW/cm2, JL) with four 40s-activation procedures with no interval (total time: 3min 20s). The temperature was measured each 40s using a digital thermometer with two type K thermocouples placed inside the PC and on dental surface (SUR). Data were analyzed with 3-way ANOVA (gel type - GT, FC and activation time) and Tukey's test. Results: A significant effect was found for the main factors FC and GT, and for their interaction. The means (SD) (in Celsius degree) were: PC:[GT={MX-6,38(3,25)a, CON-7,70(2,91)b}, FC={OP-5,51(2,54)a, JL-8,56(2,93)b}]; SUR: [GT={CON-9,85(3,89)a, MX-14,21(7,76)b}, FC={OP-7,32(2,50)a, JL-16,74(5,82)b}]. Conclusions: MX resulted in lower pulp chamber heating and higher gel heating than the control group. JL promoted greater heating than OP.


Assuntos
Humanos , Cavidade Pulpar , Clareamento Dental , Luz , Raios Infravermelhos
2.
Rev. odontol. UNESP ; 33(4): 163-168, out.-dez. 2004. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-510846

RESUMO

O objetivo deste estudo foi avaliar a influência da temperatura pré-polimerização e do tempo de fotoativação da resina composta na microinfiltração marginal. Para tal, 60 incisivos bovinos receberam preparos classe V na junção amelo-cementária e aplicação do sistema adesivo Prime & Bond NT (Dentsply), sendo restaurados com incremento único de Z250 (3M). Eles foram divididos em seis grupos de acordo com a temperatura e o tempo de fotoativação: G1 - o compósito foi resfriado a 5°C e fotoativado por 20 s; G2 - 5°C/40 s; G3 - o compósito foi mantido a temperatura ambiente de 24°C e fotoativado por 20 s; G4 - 24°C/40 s; G5 - o compósito foi aquecido a 54°Ce fotoativado por 20 s; G6 - 54°C/40 s. Os dentes restaurados foram imersos em água destilada a 37°C por 24 horas e posteriormente receberam acabamento, polimento e 500 ciclos térmicos (5 e 55°C). A microinfiltração foi avaliada quantitativamente em milímetros pelo método do nitratode prata seguido pela diafanização. Os dados foram submetidos a ANOVA paramétrica e teste de Tukey (α = 5%), obtendo-se um valor de p = 0,00. As médias (± desvio padrão) observadas para cada grupo foram: G6:1,7(± 1,0)a; G2:2,7(± 1,3)ab; G1:2,7(± 1,6)ab; G5:3,1(± 1,0)abc; G3:3,8(± 1,0)bc; G4:4,3(± 0,3)c. Os grupos acompanhados das mesmas letras não apresentam diferenças significantes. Pôde-se concluir que, utilizando 40 segundos de fotoativação, o aquecimentoreduziu significativamente a microinfiltração em relação à temperatura ambiente, enquanto oresfriamento não produziu efeitos significantes. Utilizando 20 segundos de fotoativação, a variação de temperatura não exerceu efeitos significativos.


Assuntos
Infiltração Dentária , Resinas Compostas , Temperatura
3.
J Adhes Dent ; 6(1): 33-42, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15119585

RESUMO

PURPOSE: To evaluate the effects of removing dentin collagen exposed by acid etching on the microleakage of bonded restorations with and without flowable composite application and submitted to thermocycling and long-term water storage. MATERIALS AND METHODS: Standardized Class V cavities were prepared in 180 bovine incisors. They were randomly assigned to three groups according to the adhesive technique used. Conventional group (C): Single Bond was applied according to the manufacturer's instructions and Z250 composite was placed. Hypochlorite group (H): After acid etching a 10% NaOCl aqueous solution was applied for 1 min, then Single Bond and Z250 were applied. Hypochlorite and Flowable group (HF): Similar to group H, but following adhesive application, a thin layer of Natural Flow flowable composite was applied before the Z250. Each group was divided into three subgroups (0, 6, 12), which remained immersed in distilled water for 24 h or 6 or 12 months and underwent 500, 1500 or 2500 thermal cycles, respectively. At the end of each storage time, the specimes were stained with silver nitrate, decalcified, immersed in methyl salicylate for clearing and observed under a stereomicroscope to determine microleakage (scores 0 to 4). The data were analyzed using the Kruskal-Wallis and the Multiple Comparison Tests (alpha = 0.05). RESULTS: After 12 months, every group showed significant increases in microleakage. There was no significant difference between Groups H and HF for the three different periods of time, but they showed statistically less microleakage than Group C. CONCLUSION: The removal of dentinal collagen reduced the marginal microleakage when compared to the conventional technique. The use of the flowable composite did not produce significant effects. No technique was completely effective in preventing microleakage.


Assuntos
Colágeno/ultraestrutura , Colagem Dentária , Infiltração Dentária/patologia , Dentina/ultraestrutura , Condicionamento Ácido do Dente , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bovinos , Resinas Compostas/química , Adesivos Dentinários/química , Oxidantes/química , Ácidos Fosfóricos/química , Distribuição Aleatória , Coloração pela Prata , Hipoclorito de Sódio/química , Estatísticas não Paramétricas , Fatores de Tempo
4.
Pós-Grad. Rev ; 3(2): 69-80, jul.-dez. 2000. ilus, tab, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-854038

RESUMO

O objetivo deste estudo foi avaliar a qualidade do contato proximal obtido após a realização de restaurações classe II em resina composta. Cavidades proximais foram preparadas em 50 premolares hígidos, utilizando a ponta ultra-sônica SONICSYS-approx tamanho 2. Todos os dentes receberam o mesmo tipo de matriz e cunha e foram divididos em cinco grupos de acordo com o material e técnica restauradora aplicada: A-Z100 por técnica incremental. B-Z100 + "pérola" de resina pré-polimerizada, C-Definite, D-SONICSYS-inlays, E-liga de amálgama Permite (grupo controle). A qualidade do contato foi verificada medindo-se, através de um dinamômetro, a força necessária para um fio dental transpor o contato. As medições foram realizadas antes do preparo cavitário e após o término das restaurações. Os testes t (Student), Levene, ANOVA e Tukey foram aplicados aos dados obtidos. Os resultados mostraram que nenhum dos materiais estéticos testados proporcionou contatos tão fortes quanto o amálgama. A resina Z100 aplicada por técnica incremental apresentou o pior desempenho, enquanto que as "pérolas" de resina e a resina condensável Definite mostraram-se mais favoráveis que a primeira. A utilização das inlays pré-fabricadas SONICSYS, cimentadas nos preparos padronizados, mostrou-se a técnica mais favorável para a reprodução dos contatos interdentais


Assuntos
Resinas Compostas , Materiais Dentários/análise
5.
Pós-Grad. Rev ; 3(2): 108-20, jul.-dez. 2000. ilus, tab, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-854042

RESUMO

O objetivo deste estudo foi avaliar o efeito de dois seladores de superfície e um selante de fóssulas e fissuras no desgaste e no desempenho clínico de restaurações de resina composta. Para tal, foram selecionados 44 molares em oclusão, que necessitassem de restaurações classe I. Eles foram restaurados com a resina composta Z100 (3M), e após o acabamento e polimento foram divididos em quatro grupos: o grupo 1 foi considerado controle e não recebeu nenhum tratamento adicional. Os demais grupos receberam selamento de superfície: Grupo 2 - Protect It (Jeneric Pentron), Grupo 3 - OptiGuard (Kerr), Grupo 4 - Conseal F (SDI - selantes de fossas e fissuras). As restaurações foram avaliadas clinicamente, por 24 meses, atribuindo-se os escores S (satisfatório), A (aceitável) e I (insatisfatório) quanto a cor, textura de superfície, forma anatômica, manchamento marginal, retenção de placa bacteriana e fratura ou queda. A cada 6 meses foram obtidos modelos de estudo, sendo estes analisados quanto a quantidade de desgaste comparando-os, através de um estereomicroscópio, a modelos padronizados. Os dados clínicos foram submetidos ao teste de Fisher e não foram constatadas diferenças estatisticamente significantes entre os grupos em todos os intervalos de tempo e categorias avaliadas. Os dados obtidos através da avaliação de modelos foram submetidos aos testes de Kruskall-Wallis e Dunn onde observamos que, aos 12 meses, o grupo 4 apresentou uma média de desgaste significantemente menor que o grupo Controle e, não foram constatadas diferenças significantes entre os grupos 1, 2 e 3. Aos 18 meses, o grupo 3 apresentou uma média significantemente menor de desgaste que os grupos 1 e 2, porém não significante em relação ao grupo 4. Aos 24 meses não foram detectadas diferenças estatisticamente significantes de desgaste entre todos os grupos. Podemos concluir que, embora, clinicamente não tenham sido constatadas diferenças significantes, através dos modelos pudemos constatar que o OptiGuard e Conseal F proporcionaram maior resistência ao desgaste. O protect It não apresentou efeitos significantes em relação ao desgaste. Aos 24 meses, os protetores de superfície já não possuíam efetividade


Assuntos
Resinas Compostas , Selantes de Fossas e Fissuras/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...